PRODUCT DETAILS
FLN36-12D,FLRN36-12D AC high voltage sulfur hexafluoride load switch, load switch-fuse combination electrical appliance and cable head type load switch are our company'sdigestion and absorption of foreign advanced technology, combined with my country'soperating requirements, self-designed and developed become. The product has undergonea comprehensive type test, and its performance meets the requirements of GB3804 "3~63kVAC High Voltage Load Switch",GB16926 "High Voltage Load Switch-Fuse CombinationElectric Appliance"EC60265, EC60420 standards. The product has a three-position arcextinguishing chamber of "combining-dividing-grounding",with reliable interlocking, highfracture insulation strength, large creepage design, and the outlet end is protected by avoltage equalizing protective cover. lt is equipped with a cable head type load switch, theoutlet end is equipped with a touchable cable front connector, and the inlet and outlet linesare installed with high-voltage cables, which are used in the cable branch (connection) box.
serial number | name | unit | (nx)fln36-12d | (nx)flrn36-12d | |
1 | rated voltage | kv | 12 | 12 | |
2 | rated frequency | hz | 50 | 50 | |
3 | rated current | a | 630 | 125 | |
4 | load switch rated short-time withstand current / rated short-circuit duration | ka/s | 20/3 | - | |
earthing switch rated short-time withstand current/rated short-circuit duration | ka/s | 20/2 | - | ||
5 | rated peak withstand current and rated short-circuit making current | ka | 50 | 125(expect) | |
6 | ratedbreakingcurrent | active load breaking current | a | 630 | - |
closed-loop breaking current | a | 630 | - | ||
5% of rated active load breaking current | a | 31.5 | - | ||
disconnect cable charging current | a | 10 | - | ||
breaking no-load transformer capacity | kva | 1250 | 1250 | ||
break transfer current | a | - | 1700 | ||
expected short-circuit breaking current | ka | - | 50 | ||
7 | rated absoluteedge level | 1min power frequency withstand voltage phase-to-phase, to qround/fracture | kv | 42/48 | 42/48 |
lightning impulse withstand voltage phase-to-phase to ground/ fractur | kv | 75/85 | 75/85 | ||
8 | main circuit ground circuit mechanical life | 3000/2000 | 2000/2000 | ||
9 | sf6 rated air pressure (gauge pressure at 20° c) | mpa | 0.04~0.05 | 0.04~0.05 |
Conditions of Use
>Normal use conditions
>Ambient temperature-25°C~+40°C
> Altitude: no more than 2000m
> Humidity conditions: the average relative humidity does not exceed 95%, the averagemonthly relative humidity does not exceed 90%, the average daily water vapor pressure doesnot exceed 2.2kPa, and the average monthly water vapor pressure
Not more than 1.8kPa
> The surrounding air is not significantly polluted by dust, smoke, corrosive and/or flammablegases, steam or salt mist
> Vibration or ground motion from outside of switchgear and control equipment is negligible> The amplitude of electromagnetic interference induced in the secondary system shall notexceed 1.6kV.
> Special Conditions of Use
According to the national standard GB/T11022-1999,"Common technical requirements forhigh-voltage switchgear and control equipment standards", the circuit breaker should operateunder normal conditions of use. lf the working conditions used by the user are different fromthe normal use conditions, such as: the installation site is at an altitude of more than 2000m.the ambient air temperature exceeds the limit specified in the normal use conditions, or thehigh humidity is prone to condensation, it should be negotiated with the manufacturer, and reached consensus.