Aierway 12KV Indoor AC high voltage earthing switch JN17-12/40

The JN17-12/40 grounding switch is widely used in medium-voltage (12kV) power distribution systems and is commonly installed in the following types of switchgear

Category: Tag: Brand:

Description

JN17-12/40 Grounding Switch Introduction

The JN17-12/40 is a high-voltage grounding switch designed for use in 12kV power distribution systems. Its primary functions include:

  1. Safety Grounding – Provides reliable earthing for de-energized circuits during maintenance, protecting personnel from accidental energization or residual charges.

  2. Isolation Verification – Works in conjunction with circuit breakers/disconnectors to visibly confirm electrical isolation before maintenance.

  3. Fault Protection – Some models may short-circuit fault currents (40kA rated) when used with fault-making capability, aiding system protection.

  4. System Compatibility – Typically installed in switchgear, ring main units, or substations as a visible grounding point.

Key features often include:

  • 12kV rated voltage / 40kA short-circuit withstand capacity

  • Manual or motorized operation options

  • Mechanical interlocking with other switching devices to prevent misoperation

This device complies with IEC/GIS standards for medium-voltage equipment, ensuring operational safety in power grids.

Technical Parameter

No. Item Unit Data
1 Rated voltage KV 12
2 Rated short time withstand current KA 40
3 Rated short circuit withstand time S 4
4 Rated short circuit making current KA 80
5 Rated peak withstand current KA 80
6 Rated insulation level 1min power frequency withstand voltage 42
7 Lightning impulse withstand voltage 75
Mechanical life 2000

 

(Unit: mm)
Specification E F G H D
JN17-12/40-210 210 50 185 655 516
JN17-12/40-220 220 50 185 675 536
JN17-12/40-230 230 50 185 695 556
JN17-12/40-250 250 50 185 735 596
JN17-12/40-275 275 50 210 810 646

The JN17-12/40 grounding switch is widely used in medium-voltage (12kV) power distribution systems and is commonly installed in the following types of switchgear:

1. Metal-Enclosed Switchgear (Indoor/Outdoor)

  • Used in KYN, XGN, or other fixed/movable switchgear panels to provide a visible grounding point for maintenance safety.

  • Often integrated with circuit breakers and disconnectors to ensure proper isolation before grounding.

2. Ring Main Units (RMUs)

  • Installed in SF₆-insulated or air-insulated RMUs for cable grounding during feeder maintenance.

  • Ensuresafe operation in urban distribution networks and underground cable systems.

3. Compact Substations & Prefabricated Switchgear

  • Used in box-type substations (e.g., Euro-style compact substations) to provide a reliable grounding solution for transformers and cables.

4. Wind/Solar Power Systems

  • Applied in renewable energy switchgear to ground circuits during turbine or PV system maintenance.

5. Railway & Industrial Power Systems

  • Installed in traction power supply units and industrial switchgear for safe maintenance of high-voltage equipment.

Key Compatibility Features:

✔ Interlocking Mechanism – Prevents closing on live circuits (when paired with disconnectors).
✔ Motorized/Manual Operation – Adaptable to automated or manual switchgear systems.
✔ 40kA Fault Withstand – Suitable for high short-circuit current applications.

This grounding switch ensures compliance with IEC 62271 standards for medium-voltage switchgear safety.

Go to Top